ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Metal grain structure resolved with table-top micro-tomographic system

NázevTitle
Metal grain structure resolved with table-top micro-tomographic systemMetal grain structure resolved with table-top micro-tomographic system
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
D. Vavřík, P. Soukup
Klíčová slovaKeywords
Inspection with x-rays, Computerized Tomography, Computed Radiography, Detection of defects
DOIDOI
10.1088/1748-0221/6/11/C11034
Časopis / citaceJournal / citation
Journal of Instrumentation 6(11), C11034-C11034 (2011) · ISSN 1748-0221
RokYear
2011
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Využití radionuklidů a ionizujícího zářeníApplication of radionuclides and ionising radiation; Vyhodnocování energie odpovědné za růst trhlinyEvaluation of the energy responsible for fracture advancing
CitovánoCited by
6 (OpenAlex)
2012: 32013: 22014: 02015: 02016: 1
Plný text (open access)Full text (open access)
https://iopscience.iop.org/article/10.1088/1748-0221/6/11/C11034/pdf
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

X-ray transmission radiograms of Aluminum alloy contain relatively low contrast features induced by variations of the material chemical composition. Generally, these variations are strongly connected with grains of the metal, where these differ from each to other. Although grains of the studied material have typically dimensions of tens of micrometers only, the material variations can enable the observation of geometry and orientations of grains in the specimen volume employing advanced X-ray micro tomographic method. Analysis of such tiny structures requires high dynamic range of acquired radiograms with high signal to noise ratio and appropriate geometrical magnification. These requirements can be fully satisfied by using the pixelated single photon counting device Medipix, a precise micro-tomographic setup and appropriate data processing. Results will be demonstrated with an Aluminum alloy bar specimen.

X-ray transmission radiograms of Aluminum alloy contain relatively low contrast features induced by variations of the material chemical composition. Generally, these variations are strongly connected with grains of the metal, where these differ from each to other. Although grains of the studied material have typically dimensions of tens of micrometers only, the material variations can enable the observation of geometry and orientations of grains in the specimen volume employing advanced X-ray micro tomographic method. Analysis of such tiny structures requires high dynamic range of acquired radiograms with high signal to noise ratio and appropriate geometrical magnification. These requirements can be fully satisfied by using the pixelated single photon counting device Medipix, a precise micro-tomographic setup and appropriate data processing. Results will be demonstrated with an Aluminum alloy bar specimen.