Utilization of dual-source X-ray tomography for reduction of scanning time of wooden samples

NázevTitle
Utilization of dual-source X-ray tomography for reduction of scanning time of wooden samplesUtilization of dual-source X-ray tomography for reduction of scanning time of wooden samples
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
T. Fíla, I. Kumpová, I. Jandejsek, M. Kloiber, D. Tureček, D. Vavřík
Klíčová slovaKeywords
Computerized Tomography (CT) and Computed Radiography (CR), Overall mechanics design (support structures and materials, vibration analysis etc), Inspection with x-rays
DOIDOI
10.1088/1748-0221/10/05/C05008
Časopis / citaceJournal / citation
Journal of Instrumentation 10(05), C05008-C05008 (2015) · ISSN 1748-0221
RokYear
2015
JazykLanguage
eng
ZáznamyRecords
CitovánoCited by
19 (OpenAlex)
2016: 52017: 12018: 02019: 02020: 12021: 02022: 12023: 32024: 62025: 12026: 1
Plný text (open access)Full text (open access)
https://iopscience.iop.org/article/10.1088/1748-0221/10/05/C05008/pdf
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

We present a novel dual-source/dual energy (DSCT/DECT) micro-tomography system including results of high-resolution DSCT reconstruction. The DSCT micro-tomography setup was designed as a multi-purpose X-ray imaging device equipped with two pairs of X-ray tubes and detectors in orthogonal arrangement with independent control of beam parameters. Both pairs (tube-detector) are mounted on a computer numerical control positioning system and can be independently set up to different geometries (e.g. with different magnification of each pair). In this work the simultaneous scanning of the object by two tube-detector pairs was used for approximately half reduction of tomography scanning time. The developed imaging procedure was applied for scanning of a wooden sample locally damaged during a semi-destructive test for assessment of wood quality. Prior to the tomography measurements the setup geometry was precisely adjusted in terms of magnification, horizontal and vertical tube-specimen-detector alignment of both pairs. DSCT measurements were carried out in sequence (2 x 90 degrees for each tube) with identical 100 mu m image resolution. It was proven that the presented experimental setup combined with appropriate control technique significantly reduces tomography scanning time of materials with complex micro-structure.

We present a novel dual-source/dual energy (DSCT/DECT) micro-tomography system including results of high-resolution DSCT reconstruction. The DSCT micro-tomography setup was designed as a multi-purpose X-ray imaging device equipped with two pairs of X-ray tubes and detectors in orthogonal arrangement with independent control of beam parameters. Both pairs (tube-detector) are mounted on a computer numerical control positioning system and can be independently set up to different geometries (e.g. with different magnification of each pair). In this work the simultaneous scanning of the object by two tube-detector pairs was used for approximately half reduction of tomography scanning time. The developed imaging procedure was applied for scanning of a wooden sample locally damaged during a semi-destructive test for assessment of wood quality. Prior to the tomography measurements the setup geometry was precisely adjusted in terms of magnification, horizontal and vertical tube-specimen-detector alignment of both pairs. DSCT measurements were carried out in sequence (2 x 90 degrees for each tube) with identical 100 mu m image resolution. It was proven that the presented experimental setup combined with appropriate control technique significantly reduces tomography scanning time of materials with complex micro-structure.