ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Obelix, a New Low-Background HPGe at Modane Underground Laboratory

NázevTitle
Obelix, a New Low-Background HPGe at Modane Underground LaboratoryObelix, a New Low-Background HPGe at Modane Underground Laboratory
Druh výsledkuResult type
Příspěvek ve sborníkuProceedings paper
AutořiAuthors
P. Loaiza, V. Brudanin, F. Piquemal, E. Rukhadze, N. Rukhadze, I. Štekl, G. Warot, M. Zampaolo
Klíčová slovaKeywords
gamma- Ray, spectrometry, low background
KonferenceConference
5th Topical Workshop on Low Radioactivity Techniques (Seattle, United States, 2015-03-18)
DOIDOI
10.1063/1.4928012
Časopis / citaceJournal / citation
In: AIP Conference Proceedings 1672, AIP Publishing LLC, 2015, pp. 130002 · ISSN 0094-243X
RokYear
2015
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Speciální detekční techniky používané v podzemních experimentech, na urychlovačích v CERN a v NMRAdvanced detection methods used in underground physics, on accelerators at CERN and NMR; Neurychlovačová astročásticová fyzika v podzemní laboratoři LSM (Francie)Non-accelerator astroparticle physics in the Modane Underground Laboratory (LSM, France); Příspěvek k rozšíření velké výzkumné infrastruktury evropského významuContribution of the Czech Republic to the extension of the large research infrastructure of European importance
CitovánoCited by
13 (INSPIRE-HEP)
2017: 42018: 32019: 12020: 02021: 22022: 12023: 12024: 02025: 1
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

An ultra-low background coaxial HPGe detector for gamma-ray spectrometry with a relative efficiency of 160%, corresponding to a 600 cm3 Ge crystal, was installed at the Laboratoire Souterrain de Modane, France (4800 m.w.e). To reduce the instrinsic detector background, all parts involved in the detector cryostat were selected for their low radioactivity contamination. A shielding, composed of an inner layer of roman lead and an external layer of regular lead was installed, together with a system to reduce the Rn level inside the sample chamber. The shielding was designed to allow the measurement of Marinelli-shaped samples. We present the constructional details which lead to a remarkable low detector background of 73 cts/kg·d in [40, 3000] keV. Measured samples showed that sensitivities about 100 μBq/kg in 226Ra and 228Th are reached for samples of some kg and 30 days of lifetime.

An ultra-low background coaxial HPGe detector for gamma-ray spectrometry with a relative efficiency of 160%, corresponding to a 600 cm3 Ge crystal, was installed at the Laboratoire Souterrain de Modane, France (4800 m.w.e). To reduce the instrinsic detector background, all parts involved in the detector cryostat were selected for their low radioactivity contamination. A shielding, composed of an inner layer of roman lead and an external layer of regular lead was installed, together with a system to reduce the Rn level inside the sample chamber. The shielding was designed to allow the measurement of Marinelli-shaped samples. We present the constructional details which lead to a remarkable low detector background of 73 cts/kg·d in [40, 3000] keV. Measured samples showed that sensitivities about 100 μBq/kg in 226Ra and 228Th are reached for samples of some kg and 30 days of lifetime.

↑ NahoruTop