ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Measurement of the radon diffusion through a nylon foil for different air humidities

NázevTitle
Measurement of the radon diffusion through a nylon foil for different air humiditiesMeasurement of the radon diffusion through a nylon foil for different air humidities
Druh výsledkuResult type
Příspěvek ve sborníkuProceedings paper
AutořiAuthors
F. Mamedov, I. Štekl, K. Smolek
Klíčová slovaKeywords
radon
KonferenceConference
5th Topical Workshop on Low Radioactivity Techniques (Seattle, United States, 2015-03-18)
DOIDOI
10.1063/1.4928023
Časopis / citaceJournal / citation
In: AIP Conference Proceedings 1672, AIP Publishing LLC, 2015, pp. 140007 · ISSN 0094-243X
RokYear
2015
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Speciální detekční techniky používané v podzemních experimentech, na urychlovačích v CERN a v NMRAdvanced detection methods used in underground physics, on accelerators at CERN and NMR; Technologie pro získání čistých nadzemních prostor s minimální aktivitou radonu a podzemních prostor s potlačením všech typů ionizujícího zářeníTechnology for obtaining low radon activity clean room at surface and underground laboratories with suppression of all types of ionizing radiation.; Neurychlovačová astročásticová fyzika v podzemní laboratoři LSM (Francie)Non-accelerator astroparticle physics in the Modane Underground Laboratory (LSM, France)
CitovánoCited by
3 (INSPIRE-HEP)
2016: 12017: 12018: 02019: 1
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

The dependency of the radon penetration through a nylon foil on air humidity was measured. Such information is needed for the tracking part of the SuperNEMO detector, which is planned to be shielded against radon by nylon foil and in which the air humidity is not negligible. The long term measurements of radon penetration through nylon foils for different air humidities were performed with the radon diffusion setup constructed at the IEAP, CTU in Prague. The setup consists of two stainless steel hemispheres with Si detector in each of them. Both hemispheres are separated by the tested foil. While the left hemisphere contains high Rn activity, the right part contains only activity caused by the radon penetration through the tested foil. Obtained results of this study with a nylon foil with the thickness of 50 μm are presented.

The dependency of the radon penetration through a nylon foil on air humidity was measured. Such information is needed for the tracking part of the SuperNEMO detector, which is planned to be shielded against radon by nylon foil and in which the air humidity is not negligible. The long term measurements of radon penetration through nylon foils for different air humidities were performed with the radon diffusion setup constructed at the IEAP, CTU in Prague. The setup consists of two stainless steel hemispheres with Si detector in each of them. Both hemispheres are separated by the tested foil. While the left hemisphere contains high Rn activity, the right part contains only activity caused by the radon penetration through the tested foil. Obtained results of this study with a nylon foil with the thickness of 50 μm are presented.

↑ NahoruTop