ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Data acquisition system for the socal plane detector of the mass separator MASHA

NázevTitle
Data acquisition system for the socal plane detector of the mass separator MASHAData acquisition system for the socal plane detector of the mass separator MASHA
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
A.S. Novoselov, A.M. Rodin, Š. Motyčák, Ľ. Krupa
Klíčová slovaKeywords
superheavy elements
DOIDOI
10.1134/S154747711605037X
Časopis / citaceJournal / citation
Physics of Particles and Nuclei Letters 13(5), 595-597 (2016) · ISSN 1547-4771
RokYear
2016
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Spolupráce ČR s SUJV Dubna v teoretické a jaderné fyzice a při využití jaderných metod v dalších oborechCooperation of Czech Republic with JINR Dubna in the theoretical and nuclear physics and application of nuclear methods in other fields; Institucionální podpora na rozvoj výzkumné org.Institucionální podpora na rozvoj výzkumné org.
CitovánoCited by
1 (OpenAlex)
2020: 1
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

The results of the development and the general information about the data acquisition system which was recently created at the MASHA setup (Flerov laboratory of nuclear reactions at Joint institute for nuclear research) are presented. The main difference from the previous system is that we use a new modern platform, National Instruments PXI with XIA multichannel high-speed digitizers (250 MHz 12 bit 16 channels). At this moment system has 448 spectrometric channels. The software and its features for the data acquisition and analysis are also described. The new DAQ system expands precision measuring capabilities of alpha decays and spontaneous fission at the focal plane position-sensitive silicon strip detector which, in turn, increases the capabilities of the setup in such a field as low-yield registration of elements.

The results of the development and the general information about the data acquisition system which was recently created at the MASHA setup (Flerov laboratory of nuclear reactions at Joint institute for nuclear research) are presented. The main difference from the previous system is that we use a new modern platform, National Instruments PXI with XIA multichannel high-speed digitizers (250 MHz 12 bit 16 channels). At this moment system has 448 spectrometric channels. The software and its features for the data acquisition and analysis are also described. The new DAQ system expands precision measuring capabilities of alpha decays and spontaneous fission at the focal plane position-sensitive silicon strip detector which, in turn, increases the capabilities of the setup in such a field as low-yield registration of elements.

↑ NahoruTop