ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

MiniPIX Timepix3 - A miniaturized radiation camera with onboard data processing for online characterization of wide-intensity mixed-radiation fields

NázevTitle
MiniPIX Timepix3 - A miniaturized radiation camera with onboard data processing for online characterization of wide-intensity mixed-radiation fieldsMiniPIX Timepix3 - A miniaturized radiation camera with onboard data processing for online characterization of wide-intensity mixed-radiation fields
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
C. Granja, J. Jakubek, P. Soukup, M. Jakubek, S. Gohl, B. Bergmann, S. Pospíšil, M. Malich
Klíčová slovaKeywords
Space, LEO
DOIDOI
10.1088/1748-0221/17/03/C03019
Časopis / citaceJournal / citation
Journal of Instrumentation 17(03), C03019 (2022) · ISSN 1748-0221
RokYear
2022
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Institucionální podpora na rozvoj výzkumné org.Institucionální podpora na rozvoj výzkumné org.
CitovánoCited by
31 (OpenAlex)
2022: 12023: 62024: 102025: 112026: 3
Plný text (open access)Full text (open access)
https://iopscience.iop.org/article/10.1088/1748-0221/17/03/C03019/pdf
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

The miniaturized radiation camera MiniPIX TPX3 is designed for detailed and wide range measurements of mixed-radiation fields present in many applications such as radiotherapy and space radiation in outer orbit. The highly integrated instrumentation utilizes a single connector for control and readout for flexible measurements and quick deployment. The device features an option to process the registered data on the same device with limited resolution and basic particle type resolving power. A novel readout and data processing technique exploits the detector high granularity and double per-pixel signal electronics to measure and characterize radiation fields of high intensity over a wide range with basic particle-type discrimination.

The miniaturized radiation camera MiniPIX TPX3 is designed for detailed and wide range measurements of mixed-radiation fields present in many applications such as radiotherapy and space radiation in outer orbit. The highly integrated instrumentation utilizes a single connector for control and readout for flexible measurements and quick deployment. The device features an option to process the registered data on the same device with limited resolution and basic particle type resolving power. A novel readout and data processing technique exploits the detector high granularity and double per-pixel signal electronics to measure and characterize radiation fields of high intensity over a wide range with basic particle-type discrimination.

↑ NahoruTop