ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Application of 2 x 5 MPX3 camera with monolithic sensor for phase contrast imaging and computed tomography

NázevTitle
Application of 2 x 5 MPX3 camera with monolithic sensor for phase contrast imaging and computed tomographyApplication of 2 x 5 MPX3 camera with monolithic sensor for phase contrast imaging and computed tomography
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
D. Vavrik, J. Dudák, X. Kumpova, J. Žemlička
Klíčová slovaKeywords
Medipix 3, Phase contrast imaging, Delamination, Carbon fibre composite
DOIDOI
10.1088/1748-0221/17/03/C03020
Časopis / citaceJournal / citation
Journal of Instrumentation 17(03), C03020 (2022) · ISSN 1748-0221
RokYear
2022
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Inženýrské aplikace fyziky mikrosvětaEngineering applications of microworld physics
Plný text (open access)Full text (open access)
https://iopscience.iop.org/article/10.1088/1748-0221/17/03/C03020/pdf
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

This work focuses on the non-destructive identification of delamination in layered structures utilizing the X-ray phase contrast effect. This effect naturally occurs on sharp edges, material interfaces and fine textures, and can be retrieved from radiographic data even without any grating in special cases, as will be demonstrated for the layered carbon fibre reinforced plastic composites used in the aerospace industry. Such delamination can be described as the local disbonding of composite layers, which often occurs due to the cyclic loading of the structural elements while in service. Such a flaw may significantly decrease its bearing capacity, and therefore periodic non-destructive inspection is needed. Aside from ultrasound inspection, which provides limited resolution and detectability, X-ray imaging and tomography is widely used in practise. Nevertheless, the identification of delamination may be difficult utilizing X-ray computed tomography, as delaminated faces may remain in contact - the defect has negligible volume. On the other hand, the distance between faces is not relevant for X-ray phase contrast imaging. In addition, access to the structural elements is often limited for X-ray imaging. For shaped parts, it will be shown in this work that limited access is not as critical a problem in comparison with standard computed tomography.

This work focuses on the non-destructive identification of delamination in layered structures utilizing the X-ray phase contrast effect. This effect naturally occurs on sharp edges, material interfaces and fine textures, and can be retrieved from radiographic data even without any grating in special cases, as will be demonstrated for the layered carbon fibre reinforced plastic composites used in the aerospace industry. Such delamination can be described as the local disbonding of composite layers, which often occurs due to the cyclic loading of the structural elements while in service. Such a flaw may significantly decrease its bearing capacity, and therefore periodic non-destructive inspection is needed. Aside from ultrasound inspection, which provides limited resolution and detectability, X-ray imaging and tomography is widely used in practise. Nevertheless, the identification of delamination may be difficult utilizing X-ray computed tomography, as delaminated faces may remain in contact - the defect has negligible volume. On the other hand, the distance between faces is not relevant for X-ray phase contrast imaging. In addition, access to the structural elements is often limited for X-ray imaging. For shaped parts, it will be shown in this work that limited access is not as critical a problem in comparison with standard computed tomography.

↑ NahoruTop