ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

The impact of helium exposure on the PMTs of the SuperNEMO experiment

NázevTitle
The impact of helium exposure on the PMTs of the SuperNEMO experimentThe impact of helium exposure on the PMTs of the SuperNEMO experiment
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
X. Aguerre, A.S. Barabash, A. Basharina-Freshville, M. Bongrand, R. Hodák, F. Koňařík, T. Křižák, M. Macko, F. Mamedov, A. Mendl, V. Palušová, M. Petro, Y. Shitov, F. Šimkovic, I. Štekl
Klíčová slovaKeywords
Detector modelling and simulations, photon detectors for UV, visible and IR photons, photomultiplier
ExperimentCollaboration
SuperNEMO
DOIDOI
10.1088/1748-0221/20/06/P06018
Časopis / citaceJournal / citation
Journal of Instrumentation 20(06), P06018 (2025) · ISSN 1748-0221
RokYear
2025
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Laboratoire Souterrain de Modane - účast ČRLaboratoire Souterrain de Modane – participation of the Czech Republic
CitovánoCited by
1 (INSPIRE-HEP)
2025: 1
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

The performance of Hamamatsu 8” photomultiplier tubes (PMTs) of the type used in the SuperNEMO neutrinoless double-beta decay experiment (R5912-MOD), is investigated as a function of exposure to helium (He) gas. Two PMTs were monitored for over a year, one exposed to varying concentrations of He, and the other kept in standard atmospheric conditions as a control. Both PMTs were exposed to light signals generated by a 207Bi radioactive source coupled to a plastic scintillator, which provided consistent large input PMT signals similar to those that are typical of the SuperNEMO experiment. The energy resolution of PMT signals corresponding to 1 MeV energy scale determined from the 207Bi decay spectrum, shows a negligible degradation with He exposure; however the rate of after-pulsing shows a clear increase with He exposure, which is modelled and compared to diffusion theory. A method for reconstructing the partial pressure of He within the PMT and a method for determining the He breakdown point, are introduced. The implications for long-term SuperNEMO operations are briefly discussed.

The performance of Hamamatsu 8” photomultiplier tubes (PMTs) of the type used in the SuperNEMO neutrinoless double-beta decay experiment (R5912-MOD), is investigated as a function of exposure to helium (He) gas. Two PMTs were monitored for over a year, one exposed to varying concentrations of He, and the other kept in standard atmospheric conditions as a control. Both PMTs were exposed to light signals generated by a 207Bi radioactive source coupled to a plastic scintillator, which provided consistent large input PMT signals similar to those that are typical of the SuperNEMO experiment. The energy resolution of PMT signals corresponding to 1 MeV energy scale determined from the 207Bi decay spectrum, shows a negligible degradation with He exposure; however the rate of after-pulsing shows a clear increase with He exposure, which is modelled and compared to diffusion theory. A method for reconstructing the partial pressure of He within the PMT and a method for determining the He breakdown point, are introduced. The implications for long-term SuperNEMO operations are briefly discussed.

↑ NahoruTop