ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Construction and characterization of a muon trigger detector for the PSI muEDM experiment

NázevTitle
Construction and characterization of a muon trigger detector for the PSI muEDM experimentConstruction and characterization of a muon trigger detector for the PSI muEDM experiment
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
G.M. Wong, T. Hu, S. Basnet, C. Dutsov
DOIDOI
10.1140/epjc/s10052-026-16145-6
Časopis / citaceJournal / citation
The European Physical Journal C 86(7), 911 (2026) · ISSN 1434-6044
RokYear
2026
JazykLanguage
eng
ZáznamyRecords
Plný text (open access)Full text (open access)
https://link.springer.com/content/pdf/10.1140/epjc/s10052-026-16145-6.pdf
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

We present the upgraded design, construction, and beam test results for the muon trigger detector (MTD) developed for the muon electric dipole moment (muEDM) experiment at the Paul Scherrer Institute (PSI) in Switzerland. This experiment aims to improve the sensitivity of the muon EDM measurement by more than three orders of magnitude beyond the current limit established by the BNL Muon g-2 experiment. Precise identification of storable incoming muons at the entrance of the storage solenoid is essential, as the MTD must rapidly trigger a pulsed magnetic kicker to confine muons in the central region of the solenoid, where a weakly focusing magnetic field is maintained. The MTD comprises two subsystems: a 0.1 mm-thick plastic scintillator “gate detector” read out by four silicon photomultipliers (SiPMs), and a 5 mm-thick CNC-machined plastic scintillator “active aperture detector” read out by six SiPMs. The geometry of the active aperture detector was optimized through acceptance studies to maximize both storage efficiency and background veto efficiency. Integrated fast electronics generate an LVTTL trigger signal under an anti-coincidence condition – a muon detected in the gate but not in the aperture – ensuring selective triggering of storable muon events for the EDM measurement. The system was tested at the PSI πE1 beamline using 22.5 MeV/c muons under scaled-down conditions to characterize detector response and trigger performance. A Geant4 simulation incorporating detailed optical photon transport and SiPM response modeling was developed and reproduces the measured event topologies with ∼97% agreement. These results validate the detector design and demonstrate the MTD’s readiness for deployment in the full muEDM Phase-1 setup.

We present the upgraded design, construction, and beam test results for the muon trigger detector (MTD) developed for the muon electric dipole moment (muEDM) experiment at the Paul Scherrer Institute (PSI) in Switzerland. This experiment aims to improve the sensitivity of the muon EDM measurement by more than three orders of magnitude beyond the current limit established by the BNL Muon g-2 experiment. Precise identification of storable incoming muons at the entrance of the storage solenoid is essential, as the MTD must rapidly trigger a pulsed magnetic kicker to confine muons in the central region of the solenoid, where a weakly focusing magnetic field is maintained. The MTD comprises two subsystems: a 0.1 mm-thick plastic scintillator “gate detector” read out by four silicon photomultipliers (SiPMs), and a 5 mm-thick CNC-machined plastic scintillator “active aperture detector” read out by six SiPMs. The geometry of the active aperture detector was optimized through acceptance studies to maximize both storage efficiency and background veto efficiency. Integrated fast electronics generate an LVTTL trigger signal under an anti-coincidence condition – a muon detected in the gate but not in the aperture – ensuring selective triggering of storable muon events for the EDM measurement. The system was tested at the PSI πE1 beamline using 22.5 MeV/c muons under scaled-down conditions to characterize detector response and trigger performance. A Geant4 simulation incorporating detailed optical photon transport and SiPM response modeling was developed and reproduces the measured event topologies with ∼97% agreement. These results validate the detector design and demonstrate the MTD’s readiness for deployment in the full muEDM Phase-1 setup.

↑ NahoruTop