APPLICATION OF THE PIN DIODE AS A DOSIMETER FOR DOSE MEASUREMENT OF SEVERAL RADIATION SOURCES
- NázevTitle
- APPLICATION OF THE PIN DIODE AS A DOSIMETER FOR DOSE MEASUREMENT OF SEVERAL RADIATION SOURCESAPPLICATION OF THE PIN DIODE AS A DOSIMETER FOR DOSE MEASUREMENT OF SEVERAL RADIATION SOURCES
- Druh výsledkuResult type
- Příspěvek ve sborníkuProceedings paper
- AutořiAuthors
- V. Sopko, J. Dammer, D. Chren, B. Sopko, F. Latal
- Klíčová slovaKeywords
- PIN dioda, dosimetry,neutrons, protons, gamma photons
- KonferenceConference
- 11th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications (Villa Olmo, Italy, 2009-10-05)
- DOIDOI
- 10.1142/9789814307529_0024
- Časopis / citaceJournal / citation
- In: Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications, WORLD SCIENTIFIC, 2010, pp. 140-144
- RokYear
- 2010
- JazykLanguage
- eng
- ZáznamyRecords
- ProjektProject
- Spolupráce ČR s CERNCollaboration of the Czech Republic with CERN
- CitovánoCited by
- 2 (OpenAlex)
- Citace ke staženíDownload citation
- TXT · BibTeX
AbstraktAbstract
Experimental PIN diodes produced for measurement of low energy gamma radiation were exposed to neutron, proton and gamma radiation sources, in an attempt to expand the area of their application. Irradiation of the PIN diode resulted in changes of IV curve. The changes of voltage at certain current were recorded and depicted in graphs.
Experimental PIN diodes produced for measurement of low energy gamma radiation were exposed to neutron, proton and gamma radiation sources, in an attempt to expand the area of their application. Irradiation of the PIN diode resulted in changes of IV curve. The changes of voltage at certain current were recorded and depicted in graphs.