ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Modular pixelated detector system with the spectroscopic capability and fast parallel read-out

NázevTitle
Modular pixelated detector system with the spectroscopic capability and fast parallel read-outModular pixelated detector system with the spectroscopic capability and fast parallel read-out
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
D. Vavřík, M. Holík, J. Jakůbek, V. Kraus, F. Krejčí, P. Soukup, D. Tureček, J. Vacík, J. Žemlička, M. Jakůbek
Klíčová slovaKeywords
X-ray detector, Modular electronics, Neutron detectors (cold, thermal, fast neutrons), Particle tracking detectors (Solid-state detectors)
DOIDOI
10.1088/1748-0221/9/06/C06006
Časopis / citaceJournal / citation
Journal of Instrumentation 9(06), C06006-C06006 (2014) · ISSN 1748-0221
RokYear
2014
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Pracoviště pro nedestruktivní testování, diagnostiku a 3D zobrazování pomocí neutronové radiografie a tomografie (2011-2015, TA0/TA)Facility for nondestructive testing, diagnostics and 3D imaging based on neutron radiography and tomography.
CitovánoCited by
9 (OpenAlex)
2014: 12015: 02016: 12017: 32018: 02019: 12020: 22021: 02022: 1
Plný text (open access)Full text (open access)
https://iopscience.iop.org/article/10.1088/1748-0221/9/06/C06006/pdf
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

A modular pixelated detector system was developed for imaging applications, where spectroscopic analysis of detected particles is advantageous e.g. for energy sensitive X-ray radiography, fluorescent and high resolution neutron imaging etc. The presented system consists of an arbitrary number of independent versatile modules. Each module is equipped with pixelated edgeless detector with spectroscopic ability and has its own fast read-out electronics. Design of the modules allows assembly of various planar and stacked detector configurations, to enlarge active area or/and to improve detection efficiency, while each detector is read-out separately. Consequently read-out speed is almost the same as that for a single module (up to 850 fps). The system performance and application examples are presented.

A modular pixelated detector system was developed for imaging applications, where spectroscopic analysis of detected particles is advantageous e.g. for energy sensitive X-ray radiography, fluorescent and high resolution neutron imaging etc. The presented system consists of an arbitrary number of independent versatile modules. Each module is equipped with pixelated edgeless detector with spectroscopic ability and has its own fast read-out electronics. Design of the modules allows assembly of various planar and stacked detector configurations, to enlarge active area or/and to improve detection efficiency, while each detector is read-out separately. Consequently read-out speed is almost the same as that for a single module (up to 850 fps). The system performance and application examples are presented.

↑ NahoruTop