New search for double electron capture in Cd-106 decay with the TGV-2 spectrometer
- NázevTitle
- New search for double electron capture in Cd-106 decay with the TGV-2 spectrometerNew search for double electron capture in Cd-106 decay with the TGV-2 spectrometer
- Druh výsledkuResult type
- Článek v časopiseJournal article
- AutořiAuthors
- C. Briancon, J. Madathiparambil Jose, E. Rukhadze, L. Fajt, R. Hodák, M. Špavorová, I. Štekl
- DOIDOI
- 10.1134/S1063778815060058
- Časopis / citaceJournal / citation
- PHYSICS OF ATOMIC NUCLEI. 2015, 78(6), 740-745. ISSN 1063-7788.
- RokYear
- 2015
- JazykLanguage
- eng
- WoSWoS
- 000361444500005
- ScopusScopus
- 2-s2.0-84941992146
- RIVRIV
- RIV/68407700:21670/15:00233358!RIV16-MSM-21670___
- ProjektProject
- Neurychlovačová astročásticová fyzika v podzemní laboratoři LSM (Francie)Non-accelerator astroparticle physics in the Modane Underground Laboratory (LSM, France)
AbstraktAbstract
A new experiment devoted to searches for double electron capture in Cd-106 decay is being performed at the Modane underground laboratory (4800 mwe) with the 32-detector TGV-2 spectrometer. The limit T (1/2)(2 nu EC/EC) > 2.0x10(20) yr at a 90%confidence level (C.L.) was obtained from a preliminary analysis of data obtained over 2250 h of measurements with about 23.2 g sample enriched in the isotope Cd-106 to 99.57%. The limits T (1/2)(KL, 2741 keV) > 0.9 x 10(20) yr and T (1/2)(KK, 2718 keV) a parts per thousand << 1.4 x 10(20) yr at a 90% C.L. on the neutrinoless decay of Cd-106 were obtained from measurements performed with the Obelix low-background spectrometer from high-purity germanium (HPGe spectrometer) for a sample of mass about 23.2 g enriched in the isotope Cd-106.
A new experiment devoted to searches for double electron capture in Cd-106 decay is being performed at the Modane underground laboratory (4800 mwe) with the 32-detector TGV-2 spectrometer. The limit T (1/2)(2 nu EC/EC) > 2.0x10(20) yr at a 90%confidence level (C.L.) was obtained from a preliminary analysis of data obtained over 2250 h of measurements with about 23.2 g sample enriched in the isotope Cd-106 to 99.57%. The limits T (1/2)(KL, 2741 keV) > 0.9 x 10(20) yr and T (1/2)(KK, 2718 keV) a parts per thousand << 1.4 x 10(20) yr at a 90% C.L. on the neutrinoless decay of Cd-106 were obtained from measurements performed with the Obelix low-background spectrometer from high-purity germanium (HPGe spectrometer) for a sample of mass about 23.2 g enriched in the isotope Cd-106.