ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

New search for double electron capture in Cd-106 decay with the TGV-2 spectrometer

NázevTitle
New search for double electron capture in Cd-106 decay with the TGV-2 spectrometerNew search for double electron capture in Cd-106 decay with the TGV-2 spectrometer
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
C. Briancon, J. Madathiparambil Jose, E. Rukhadze, L. Fajt, R. Hodák, M. Špavorová, I. Štekl
Klíčová slovaKeywords
double beta decay
DOIDOI
10.1134/S1063778815060058
Časopis / citaceJournal / citation
Physics of Atomic Nuclei 78(6), 740-745 (2015) · ISSN 1063-7788
RokYear
2015
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Neurychlovačová astročásticová fyzika v podzemní laboratoři LSM (Francie)Non-accelerator astroparticle physics in the Modane Underground Laboratory (LSM, France)
CitovánoCited by
7 (INSPIRE-HEP)
2016: 42017: 12018: 02019: 12020: 1
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

A new experiment devoted to searches for double electron capture in Cd-106 decay is being performed at the Modane underground laboratory (4800 mwe) with the 32-detector TGV-2 spectrometer. The limit T (1/2)(2 nu EC/EC) > 2.0x10(20) yr at a 90%confidence level (C.L.) was obtained from a preliminary analysis of data obtained over 2250 h of measurements with about 23.2 g sample enriched in the isotope Cd-106 to 99.57%. The limits T (1/2)(KL, 2741 keV) > 0.9 x 10(20) yr and T (1/2)(KK, 2718 keV) a parts per thousand << 1.4 x 10(20) yr at a 90% C.L. on the neutrinoless decay of Cd-106 were obtained from measurements performed with the Obelix low-background spectrometer from high-purity germanium (HPGe spectrometer) for a sample of mass about 23.2 g enriched in the isotope Cd-106.

A new experiment devoted to searches for double electron capture in Cd-106 decay is being performed at the Modane underground laboratory (4800 mwe) with the 32-detector TGV-2 spectrometer. The limit T (1/2)(2 nu EC/EC) > 2.0x10(20) yr at a 90%confidence level (C.L.) was obtained from a preliminary analysis of data obtained over 2250 h of measurements with about 23.2 g sample enriched in the isotope Cd-106 to 99.57%. The limits T (1/2)(KL, 2741 keV) > 0.9 x 10(20) yr and T (1/2)(KK, 2718 keV) a parts per thousand << 1.4 x 10(20) yr at a 90% C.L. on the neutrinoless decay of Cd-106 were obtained from measurements performed with the Obelix low-background spectrometer from high-purity germanium (HPGe spectrometer) for a sample of mass about 23.2 g enriched in the isotope Cd-106.

↑ NahoruTop