ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

A transportable source of gamma rays with discrete energies and wide range for calibration and on-site testing of gamma-ray detectors

NázevTitle
A transportable source of gamma rays with discrete energies and wide range for calibration and on-site testing of gamma-ray detectorsA transportable source of gamma rays with discrete energies and wide range for calibration and on-site testing of gamma-ray detectors
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
C. Granja, T. Slavíček, M. Kroupa, A. Owens, S. Pospíšil, Z. Janout, M. Kralik, J. Solc, O. Valach
Klíčová slovaKeywords
Transportable gamma-ray source, Gamma-ray detector calibration, Monte Carlo simulation, Dose rate measurement, Spacecraft payload qualification
DOIDOI
10.1016/j.nima.2014.10.001
Časopis / citaceJournal / citation
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 771, 1-9 (2015) · ISSN 0168-9002
RokYear
2015
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Van de Graaff - urychlovač iontů HV2500 jako laditelný zdroj neutronů v rámci české a evropské velké infrastrukturyAccelerator of ions HV2500 as tuneable neutron source in frame of Czech and European Large Infrastructure
CitovánoCited by
6 (OpenAlex)
2015: 12016: 12017: 02018: 12019: 02020: 12021: 02022: 02023: 12024: 02025: 1
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

We describe a compact and transportable wide energy range, gamma-ray station for the calibration of gamma-ray sensitive devices. The station was specifically designed for the on-site testing and calibration of gamma-ray sensitive spacecraft payloads, intended for space flight on the BepiColombo and SoIar Orbiter missions of the European Space Agency. The source is intended to serve as a calibrated reference for post test center qualification of integrated payload instruments and for preflight evaluation of scientific radiation sensors.

We describe a compact and transportable wide energy range, gamma-ray station for the calibration of gamma-ray sensitive devices. The station was specifically designed for the on-site testing and calibration of gamma-ray sensitive spacecraft payloads, intended for space flight on the BepiColombo and SoIar Orbiter missions of the European Space Agency. The source is intended to serve as a calibrated reference for post test center qualification of integrated payload instruments and for preflight evaluation of scientific radiation sensors.