Ústav technické a experimentální fyziky Institute of Experimental and Applied Physics

Search for double beta decay of Cd-106 in the TGV-2 experiment

NázevTitle
Search for double beta decay of Cd-106 in the TGV-2 experimentSearch for double beta decay of Cd-106 in the TGV-2 experiment
Druh výsledkuResult type
Příspěvek ve sborníkuProceedings paper
AutořiAuthors
NI. Rukhadze, VB Brudanin, VG. Egorov, AA. Klimenko, A. Kovalík, P. Kouba, F. Piquemal, SV. Rozov, E. Rukhadze, AV. Salamatin, F. Šimkovic, YA. Shitov, I. Štekl, VV. Timkin, EA: Yakushev
DOIDOI
10.1088/1742-6596/718/6/062049
Časopis / citaceJournal / citation
In: XIV International Conference on Topics in Astroparticle and Underground Physics (TAUP 2015). Madeira: IOPscience, 2016. Journal of Physics: Conference Series. vol. 718. ISSN 1742-6588.
JazykLanguage
eng
WoSWoS
000391490200190
ScopusScopus
2-s2.0-84981343233
RIVRIV
RIV/68407700:21670/16:00308953!RIV17-MSM-21670___
ProjektProject
Příspěvek k rozšíření velké výzkumné infrastruktury evropského významuContribution of the Czech Republic to the extension of the large research infrastructure of European importance

AbstraktAbstract

A new experimental rim of searching for double beta decay of Cd-106 was performed at the Modane underground laboratory (LSM, France, 4800 m w.e.) using the TGV-2 spectrometer, consisting of 32 planar type HPGe detectors with a total sensitive volume of similar to 400 cm(3). 16 foils of Cd-106 with an enrichment of 99.57% and a total mass of similar to 23.2 g were inserted between the entrance windows of face-to-face detectors. The limit on 2vEC/EC decay of (106)cd - T-1/2 > 3.7 x 10(20) y at 90% C.L was obtained from the preliminary calculation of experimental data accumulated for 8198 h of measurement. The limits on the resonance OvEC/EC decay of Cd-106 were obtained from the measurement of similar to 23.2 g of Cd-106 with the low-background HPGe spectrometer Obelix lasted 395 h -T-1/2 (KL, 2741 keV) > 0.9 x 10(20) y and T-1/2 (KK, 2718 keV) > 1.4 x 10(20) y at 90% C.L.

A new experimental rim of searching for double beta decay of Cd-106 was performed at the Modane underground laboratory (LSM, France, 4800 m w.e.) using the TGV-2 spectrometer, consisting of 32 planar type HPGe detectors with a total sensitive volume of similar to 400 cm(3). 16 foils of Cd-106 with an enrichment of 99.57% and a total mass of similar to 23.2 g were inserted between the entrance windows of face-to-face detectors. The limit on 2vEC/EC decay of (106)cd - T-1/2 > 3.7 x 10(20) y at 90% C.L was obtained from the preliminary calculation of experimental data accumulated for 8198 h of measurement. The limits on the resonance OvEC/EC decay of Cd-106 were obtained from the measurement of similar to 23.2 g of Cd-106 with the low-background HPGe spectrometer Obelix lasted 395 h -T-1/2 (KL, 2741 keV) > 0.9 x 10(20) y and T-1/2 (KK, 2718 keV) > 1.4 x 10(20) y at 90% C.L.