ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Detection of fast neutrons from D-T nuclear reaction using a 4H-SiC radiation detector

NázevTitle
Detection of fast neutrons from D-T nuclear reaction using a 4H-SiC radiation detectorDetection of fast neutrons from D-T nuclear reaction using a 4H-SiC radiation detector
Druh výsledkuResult type
Příspěvek ve sborníkuProceedings paper
AutořiAuthors
B. Zatko, A. Sagatova, K. Sedlackova, V. Necas, M. Solar, C. Granja
Klíčová slovaKeywords
X-ray detector, silicon-carbide, Particle detector
KonferenceConference
2015 International Conference on Applications of Nuclear Techniques (Crete, Greece, 2015-06-14)
DOIDOI
10.1142/S2010194516602350
Časopis / citaceJournal / citation
International Journal of Modern Physics: Conference Series 44, 1660235 (2016) · ISSN 2010-1945
RokYear
2016
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Van de Graaff - urychlovač iontů HV2500 jako laditelný zdroj neutronů v rámci české a evropské velké infrastrukturyAccelerator of ions HV2500 as tuneable neutron source in frame of Czech and European Large Infrastructure
CitovánoCited by
10 (OpenAlex)
2018: 22019: 02020: 22021: 12022: 02023: 22024: 3
Plný text (open access)Full text (open access)
https://www.worldscientific.com/doi/pdf/10.1142/S2010194516602350
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

The particle detector based on a high purity epitaxial layer of 4H-SiC exhibits promising properties in detection of various types of ionizing radiation. Due to the wide band gap of 4H-SiC semiconductor material, the detector can reliably operate at room and also elevated temperatures. In this work we focused on detection of fast neutrons generated the by D-T (deuterium-tritium) nuclear reaction. The epitaxial layer with a thickness of 105. m was used as a detection part. A circular Schottky contact of a Au/Ni double layer was evaporated on both sides of the detector material. The detector structure was characterized by current-voltage and capacitance-voltage measurements, at first. The results show very low current density (< 0.1 nA/cm(2)) at room temperature and good homogeneity of free carrier concentration in the investigated depth. The fabricated detectors were tested for detection of fast neutrons generated by the D-T reaction. The energies of detected fast neutrons varied from 16.0 MeV to 18.3 MeV according to the acceleration potential of deuterons, which increased from 600 kV up to 2 MV. Detection of fast neutrons in the SiC detector is caused by the elastic and inelastic scattering on the silicon or carbide component of the detector material. Another possibility that increases the detection efficiency is the use of a conversion layer. In our measurements, we glued a HDPE (high density polyethylene) conversion layer on the detector Schottky contact to transform fast neutrons to protons. Hydrogen atoms contained in the conversion layer have a high probability of interaction with neutrons through elastic scattering. Secondary generated protons flying to the detector can be easily detected. The detection properties of detectors with and without the HDPE conversion layer were compared.

The particle detector based on a high purity epitaxial layer of 4H-SiC exhibits promising properties in detection of various types of ionizing radiation. Due to the wide band gap of 4H-SiC semiconductor material, the detector can reliably operate at room and also elevated temperatures. In this work we focused on detection of fast neutrons generated the by D-T (deuterium-tritium) nuclear reaction. The epitaxial layer with a thickness of 105. m was used as a detection part. A circular Schottky contact of a Au/Ni double layer was evaporated on both sides of the detector material. The detector structure was characterized by current-voltage and capacitance-voltage measurements, at first. The results show very low current density (< 0.1 nA/cm(2)) at room temperature and good homogeneity of free carrier concentration in the investigated depth. The fabricated detectors were tested for detection of fast neutrons generated by the D-T reaction. The energies of detected fast neutrons varied from 16.0 MeV to 18.3 MeV according to the acceleration potential of deuterons, which increased from 600 kV up to 2 MV. Detection of fast neutrons in the SiC detector is caused by the elastic and inelastic scattering on the silicon or carbide component of the detector material. Another possibility that increases the detection efficiency is the use of a conversion layer. In our measurements, we glued a HDPE (high density polyethylene) conversion layer on the detector Schottky contact to transform fast neutrons to protons. Hydrogen atoms contained in the conversion layer have a high probability of interaction with neutrons through elastic scattering. Secondary generated protons flying to the detector can be easily detected. The detection properties of detectors with and without the HDPE conversion layer were compared.

↑ NahoruTop