ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

X-ray micro-CT and neutron CT as complementary imaging tools for non-destructive 3D imaging of rare silicified fossil plants

NázevTitle
X-ray micro-CT and neutron CT as complementary imaging tools for non-destructive 3D imaging of rare silicified fossil plantsX-ray micro-CT and neutron CT as complementary imaging tools for non-destructive 3D imaging of rare silicified fossil plants
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
J. Karch, J. Dudák, J. Žemlička, D. Vavřík, A. Kumpová, J. Kvaček, Z. Heřmanová, J. Šoltés, L. Viererbl, M. Morgano, A. Kaestner, P. Trtík
Klíčová slovaKeywords
Inspection with neutrons, X-ray detector
DOIDOI
10.1088/1748-0221/12/12/C12004
Časopis / citaceJournal / citation
Journal of Instrumentation 12(12), C12004-C12004 (2017) · ISSN 1748-0221
RokYear
2017
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Nedestruktivní metody jako nástroj pro studium diversity křídových rostlinNon-destructive methods as a tool for studies on diversity of Cretaceous fossil plants
CitovánoCited by
13 (OpenAlex)
2018: 12019: 02020: 22021: 42022: 12023: 22024: 12025: 2
Plný text (open access)Full text (open access)
https://iopscience.iop.org/article/10.1088/1748-0221/12/12/C12004/pdf
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

Computed tomography provides 3D information of inner structures of investigated objects. The obtained information is, however, strongly dependent on the used radiation type. It is known that as X-rays interact with electron cloud and neutrons with atomic nucleus, the obtained data often provide different contrast of sample structures. In this work we present a set of comparative radiographic and CT measurements of rare fossil plant samples using X-rays and thermal neutrons. The X-ray measurements were performed using large area photon counting detectors Timepix at IEAP CTU in Prague and Perkin Elmer flat-panel detector at Center of Excellence Telč. The neutron CT measurement was carried out at Paul Scherrer Institute using BOA beam-line. Furthermore, neutron radiography of fossil samples, provided by National Museum, were performed using a large-area Timepix detector with a neutron-sensitive converting 6LiF layer at Research Centre Rez, Czech Republic. The obtained results show different capabilities of both imaging approaches. While X-ray micro-CT provides very high resolution and enables visualization of fine cracks or small cavities in the samples neutron imaging provides high contrast of morphological structures of fossil plant samples, where X-ray imaging provides insufficient contrast.

Computed tomography provides 3D information of inner structures of investigated objects. The obtained information is, however, strongly dependent on the used radiation type. It is known that as X-rays interact with electron cloud and neutrons with atomic nucleus, the obtained data often provide different contrast of sample structures. In this work we present a set of comparative radiographic and CT measurements of rare fossil plant samples using X-rays and thermal neutrons. The X-ray measurements were performed using large area photon counting detectors Timepix at IEAP CTU in Prague and Perkin Elmer flat-panel detector at Center of Excellence Telč. The neutron CT measurement was carried out at Paul Scherrer Institute using BOA beam-line. Furthermore, neutron radiography of fossil samples, provided by National Museum, were performed using a large-area Timepix detector with a neutron-sensitive converting 6LiF layer at Research Centre Rez, Czech Republic. The obtained results show different capabilities of both imaging approaches. While X-ray micro-CT provides very high resolution and enables visualization of fine cracks or small cavities in the samples neutron imaging provides high contrast of morphological structures of fossil plant samples, where X-ray imaging provides insufficient contrast.

↑ NahoruTop