The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials

NázevTitle
The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materialsThe BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
A. S. Barabash, A. Basharina-Freshville, E. Birdsall, S. Blondel, L. Fajt, R. Hodák, F. Mamedov, P. Přidal, E. Rukhadze, A. Smetana, K. Smolek, I. Štekl
Klíčová slovaKeywords
low-radioactivity detector, radionuclide, contamination, Underground laboratory
ExperimentCollaboration
SuperNEMO
DOIDOI
10.1088/1748-0221/12/06/P06002
Časopis / citaceJournal / citation
Journal of Instrumentation 12(06), P06002-P06002 (2017) · ISSN 1748-0221
RokYear
2017
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Podzemní laboratoř LSM (Laboratoire Souterrain de Modane, Francie) - český příspěvek do výzkumné infrastruktury evropského významuUnderground laboratory LSM (Laboratoire Souterrain de Modane, Francie) - Czech contribution to research infrastructure of European level
CitovánoCited by
34 (INSPIRE-HEP)
2017: 42018: 42019: 42020: 62021: 52022: 12023: 52024: 32025: 2
Plný text (open access)Full text (open access)
https://iopscience.iop.org/article/10.1088/1748-0221/12/06/P06002/pdf
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

The BiPo-3 detector, running at the Canfranc Underground Laboratory (LaboratorioSubterraneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of Tl-208 (Th-232 chain) and Bi-214 (U-238 chain) in thin materials. The total sensitive surface area of the detector is 3.6m(2). The detector has been developed to measure the radiopurity of the selenium double fi - decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in 208Tl and 214Bi, are presented, and the validation of the BiPo- 3 measurement with a calibrated aluminium foil is discussed. Results of the 208Tl and 214Bi activity measurements of the first enriched 82Se foils of the double fi - decay SuperNEMO experiment are reported. The sensitivity of the BiPo- 3 detector for the measurement of the SuperNEMO 82Se foils is A(Tl-208) < 2 mu Bq/kg (90% C. L.) and A(Bi-214) < 140 mu Bq/kg (90% C. L.) after 6 months of measurement.

The BiPo-3 detector, running at the Canfranc Underground Laboratory (LaboratorioSubterraneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of Tl-208 (Th-232 chain) and Bi-214 (U-238 chain) in thin materials. The total sensitive surface area of the detector is 3.6m(2). The detector has been developed to measure the radiopurity of the selenium double fi - decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in 208Tl and 214Bi, are presented, and the validation of the BiPo- 3 measurement with a calibrated aluminium foil is discussed. Results of the 208Tl and 214Bi activity measurements of the first enriched 82Se foils of the double fi - decay SuperNEMO experiment are reported. The sensitivity of the BiPo- 3 detector for the measurement of the SuperNEMO 82Se foils is A(Tl-208) < 2 mu Bq/kg (90% C. L.) and A(Bi-214) < 140 mu Bq/kg (90% C. L.) after 6 months of measurement.

↑ NahoruTop