Ústav technické a experimentální fyziky Institute of Experimental and Applied Physics

Ethernet Embedded Readout Interface for Timepix2-Katherine readout for Timepix2

NázevTitle
Ethernet Embedded Readout Interface for Timepix2-Katherine readout for Timepix2Ethernet Embedded Readout Interface for Timepix2-Katherine readout for Timepix2
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
P. Burian, P. Broulim, B. Bergmann, L. Tlustos
DOIDOI
10.1088/1748-0221/15/01/C01037
Časopis / citaceJournal / citation
Journal of Instrumentation. 2020, 15(1), ISSN 1748-0221.
RokYear
2020
JazykLanguage
eng
WoSWoS
000525449100037
ScopusScopus
2-s2.0-85081681606
RIVRIV
RIV/68407700:21670/20:00342086!RIV21-MSM-21670___
ProjektProject
Inženýrské aplikace fyziky mikrosvětaEngineering applications of microworld physics

AbstraktAbstract

This paper introduces a readout system for the Timepix2. Firstly, this chip is described and the readout modes are discussed in detail. The new readout system presented is based on the Gigabit Ethernet interface and implements pre-processing, i.e. decoding of the raw pixel data, directly in the hardware. The device suppresses zero pixels, so that only useful data are sent to the computer/server. In a special independent mode, the readout can send completed data files to a remote server via SSH and does not need to use a control software. In island mode, the device stores measured data to a local storage (SD card). The process of calibration and its results are also discussed. An energy resolution of approximately 1.5 keV was achieved for 60 keV gamma-rays from an Am-241 source. We present enhanced features of the readout system facilitating measurements and data evaluation, such as the HW support of clustering and Matrix Occupation Control. The former implements the pixel clustering directly in the hardware and sends energy calibrated results of the cluster finding algorithm to the computer. The latter automatically controls acquisition time of detector in order to reduce cluster overlapping. Measurements with Timepix2 are presented in iron and electron test beams. Results show that pixels of Timepix2 saturate at a per-pixel energy deposition of 1.9 MeV.

This paper introduces a readout system for the Timepix2. Firstly, this chip is described and the readout modes are discussed in detail. The new readout system presented is based on the Gigabit Ethernet interface and implements pre-processing, i.e. decoding of the raw pixel data, directly in the hardware. The device suppresses zero pixels, so that only useful data are sent to the computer/server. In a special independent mode, the readout can send completed data files to a remote server via SSH and does not need to use a control software. In island mode, the device stores measured data to a local storage (SD card). The process of calibration and its results are also discussed. An energy resolution of approximately 1.5 keV was achieved for 60 keV gamma-rays from an Am-241 source. We present enhanced features of the readout system facilitating measurements and data evaluation, such as the HW support of clustering and Matrix Occupation Control. The former implements the pixel clustering directly in the hardware and sends energy calibrated results of the cluster finding algorithm to the computer. The latter automatically controls acquisition time of detector in order to reduce cluster overlapping. Measurements with Timepix2 are presented in iron and electron test beams. Results show that pixels of Timepix2 saturate at a per-pixel energy deposition of 1.9 MeV.