ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

New architecture for the analog front-end of Medipix4

NázevTitle
New architecture for the analog front-end of Medipix4New architecture for the analog front-end of Medipix4
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
V. Sriskaran, J. Alozy, R. Ballabriga, M. Campbell, E. Heijne
Klíčová slovaKeywords
Medipix
DOIDOI
10.1016/j.nima.2020.164412
Časopis / citaceJournal / citation
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 978, 164412 (2020) · ISSN 0168-9002
RokYear
2020
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Institucionální podpora na rozvoj výzkumné org.Institucionální podpora na rozvoj výzkumné org.
CitovánoCited by
18 (OpenAlex)
2021: 22022: 42023: 42024: 42025: 32026: 1
Plný text (open access)Full text (open access)
http://infoscience.epfl.ch/record/279762
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

The Medipix4 chip is the latest member of the family of Medipix pixel detector readout chips aimed at high rate spectroscopic X-ray imaging. Unlike its predecessors, it will be possible to tile the chip on all 4 sides permitting seamless large area coverage. This paper focuses on the development of the new Medipix4 front-end architecture capable of event-by-event data processing allowing accurate photon energy reconstruction, with charge sharing correction at an increased rate compared to Medipix3. The architecture is particularly well adapted for readout of pixelated high-Z detector materials allowing accurate energy binning of incoming hits at a fine pixel pitch. The new front-end architecture has a linear response up to 150 keV (CdTe), a count-rate capability up to 5.1x10(8) photons.mm(-2)s(-1) for 10% dead time loss at 10 keV (CdTe), and an energy resolution aiming for 2.2 keV FWHM (Full Width Half Maximum) at 60 keV (CdTe). The layout accommodates sensors with either 70 mu m or 140 mu m pitch of contacts.

The Medipix4 chip is the latest member of the family of Medipix pixel detector readout chips aimed at high rate spectroscopic X-ray imaging. Unlike its predecessors, it will be possible to tile the chip on all 4 sides permitting seamless large area coverage. This paper focuses on the development of the new Medipix4 front-end architecture capable of event-by-event data processing allowing accurate photon energy reconstruction, with charge sharing correction at an increased rate compared to Medipix3. The architecture is particularly well adapted for readout of pixelated high-Z detector materials allowing accurate energy binning of incoming hits at a fine pixel pitch. The new front-end architecture has a linear response up to 150 keV (CdTe), a count-rate capability up to 5.1x10(8) photons.mm(-2)s(-1) for 10% dead time loss at 10 keV (CdTe), and an energy resolution aiming for 2.2 keV FWHM (Full Width Half Maximum) at 60 keV (CdTe). The layout accommodates sensors with either 70 mu m or 140 mu m pitch of contacts.

↑ NahoruTop