Data acquisition system for the socal plane detector of the mass separator MASHA
- NázevTitle
- Data acquisition system for the socal plane detector of the mass separator MASHAData acquisition system for the socal plane detector of the mass separator MASHA
- Druh výsledkuResult type
- Článek v časopiseJournal article
- AutořiAuthors
- A.S. Novoselov, A.M. Rodin, Š. Motyčák, Ľ. Krupa
- DOIDOI
- 10.1134/S154747711605037X
- Časopis / citaceJournal / citation
- Physics of Particles and Nuclei Letters. 2016, 13(5), 595-597. ISSN 1547-4771.
- RokYear
- 2016
- JazykLanguage
- eng
- WoSWoS
- 000391192700015
- ScopusScopus
- 2-s2.0-84984879096
- RIVRIV
- RIV/68407700:21670/16:00349348!RIV21-MSM-21670___
- ProjektProject
- Spolupráce ČR s SUJV Dubna v teoretické a jaderné fyzice a při využití jaderných metod v dalších oborechCooperation of Czech Republic with JINR Dubna in the theoretical and nuclear physics and application of nuclear methods in other fields; Institucionální podpora na rozvoj výzkumné org.Institucionální podpora na rozvoj výzkumné org.
AbstraktAbstract
The results of the development and the general information about the data acquisition system which was recently created at the MASHA setup (Flerov laboratory of nuclear reactions at Joint institute for nuclear research) are presented. The main difference from the previous system is that we use a new modern platform, National Instruments PXI with XIA multichannel high-speed digitizers (250 MHz 12 bit 16 channels). At this moment system has 448 spectrometric channels. The software and its features for the data acquisition and analysis are also described. The new DAQ system expands precision measuring capabilities of alpha decays and spontaneous fission at the focal plane position-sensitive silicon strip detector which, in turn, increases the capabilities of the setup in such a field as low-yield registration of elements.
The results of the development and the general information about the data acquisition system which was recently created at the MASHA setup (Flerov laboratory of nuclear reactions at Joint institute for nuclear research) are presented. The main difference from the previous system is that we use a new modern platform, National Instruments PXI with XIA multichannel high-speed digitizers (250 MHz 12 bit 16 channels). At this moment system has 448 spectrometric channels. The software and its features for the data acquisition and analysis are also described. The new DAQ system expands precision measuring capabilities of alpha decays and spontaneous fission at the focal plane position-sensitive silicon strip detector which, in turn, increases the capabilities of the setup in such a field as low-yield registration of elements.