ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Investigation of BGA underfill process based on multipositional computed tomography

NázevTitle
Investigation of BGA underfill process based on multipositional computed tomographyInvestigation of BGA underfill process based on multipositional computed tomography
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
S. Hasn, M. Pichotka, K. Dušek, D. Vavřík
Klíčová slovaKeywords
metal artifact reduction, CT
DOIDOI
10.1088/1748-0221/17/06/P06037
Časopis / citaceJournal / citation
Journal of Instrumentation 17(06), P06037 (2022) · ISSN 1748-0221
RokYear
2022
JazykLanguage
eng
ZáznamyRecords
CitovánoCited by
4 (OpenAlex)
2025: 32026: 1
Plný text (open access)Full text (open access)
https://iopscience.iop.org/article/10.1088/1748-0221/17/06/P06037/pdf
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

In this paper, defect inspection related to an epoxy underfilling process between integrated circuits (ICs) and printed circuit boards (PCBs) is presented utilizing the data fusion of multipositional computed tomography (DFMCT). The work aims to verify the existence of underfilling epoxy which was not possible utilizing standard computed tomography due to strong metal artifacts created by ball grid array (BGA) packages. By interpreting the results obtained from the scanned samples, we were able to correlate the excess epoxy defects and the success of the underfilling process. We present the data fusion approach as an alternative method when traditional metal artifact reduction methods would be insufficient. The study was commenced by making a proper radiographic simulation using aRTist simulation software. The simulation enabled us to choose the right mounting positions which produce less metal artifacts for the experimental study. The DFMCT was achieved by acquiring multiple computed tomographic scans at different sample orientations. The reconstructed volumes were then aligned, and the fused volume was obtained by combining the corrected data and suppressing the disrupted data of the reconstructed volumes.

In this paper, defect inspection related to an epoxy underfilling process between integrated circuits (ICs) and printed circuit boards (PCBs) is presented utilizing the data fusion of multipositional computed tomography (DFMCT). The work aims to verify the existence of underfilling epoxy which was not possible utilizing standard computed tomography due to strong metal artifacts created by ball grid array (BGA) packages. By interpreting the results obtained from the scanned samples, we were able to correlate the excess epoxy defects and the success of the underfilling process. We present the data fusion approach as an alternative method when traditional metal artifact reduction methods would be insufficient. The study was commenced by making a proper radiographic simulation using aRTist simulation software. The simulation enabled us to choose the right mounting positions which produce less metal artifacts for the experimental study. The DFMCT was achieved by acquiring multiple computed tomographic scans at different sample orientations. The reconstructed volumes were then aligned, and the fused volume was obtained by combining the corrected data and suppressing the disrupted data of the reconstructed volumes.

↑ NahoruTop