ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

APPARATUS FOR LOCALIZATION AND DOSIMETRY OF WOUNDS WITH RADIOACTIVE CONTAMINATION

NázevTitle
APPARATUS FOR LOCALIZATION AND DOSIMETRY OF WOUNDS WITH RADIOACTIVE CONTAMINATIONAPPARATUS FOR LOCALIZATION AND DOSIMETRY OF WOUNDS WITH RADIOACTIVE CONTAMINATION
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
T. Slavíček, J. Broulím, M. Prokop, P. Rubovič, P. Fojtík
Klíčová slovaKeywords
robotic, radioactive wounds, localisation
DOIDOI
10.1093/rpd/ncac121
Časopis / citaceJournal / citation
Radiation Protection Dosimetry 198(9-11), 693-697 (2022) · ISSN 0144-8420
RokYear
2022
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Detektor radioaktivního znečištění ran a poraněníDetector of the radioactive contamination in wounds
CitovánoCited by
1 (OpenAlex)
2026: 1
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

Disasters involving radioactive materials are one of the most dangerous accidents a living organism can be exposed to. Individuals and first responders are in risk during accidents or interventions, due to radioactive debris impact, due to the use of depleted uranium ammunition or a malevolent act against individuals. Moreover, radioactive contamination of wounds causes internal exposure in the body and standard decontamination procedures cannot be applied. In order to deal with such situations, we are developing a measurement system consisting of a robotic arm, an array of various detectors and a corresponding methodology, which allows quantifying timely the spatial distribution of contamination and the radiation dose for the adequate medical response. The aim of this publication is to the present current status of the development of the described apparatus.

Disasters involving radioactive materials are one of the most dangerous accidents a living organism can be exposed to. Individuals and first responders are in risk during accidents or interventions, due to radioactive debris impact, due to the use of depleted uranium ammunition or a malevolent act against individuals. Moreover, radioactive contamination of wounds causes internal exposure in the body and standard decontamination procedures cannot be applied. In order to deal with such situations, we are developing a measurement system consisting of a robotic arm, an array of various detectors and a corresponding methodology, which allows quantifying timely the spatial distribution of contamination and the radiation dose for the adequate medical response. The aim of this publication is to the present current status of the development of the described apparatus.

↑ NahoruTop