ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Measurement of the energy response of the ATLAS calorimeter to charged pions from W-+/- -> tau(+/-) (->pi(+/-)nu(tau))nu(tau) events in Run 2 data

NázevTitle
Measurement of the energy response of the ATLAS calorimeter to charged pions from W-+/- -> tau(+/-) (->pi(+/-)nu(tau))nu(tau) events in Run 2 dataMeasurement of the energy response of the ATLAS calorimeter to charged pions from W-+/- -> tau(+/-) (->pi(+/-)nu(tau))nu(tau) events in Run 2 data
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
B. Abbott, D. C. Abbott, A. Abud, K. Abeling, B. Ali, K. Augsten, B. Bergmann, T. Billoud, M. Havránek, Z. Hubáček, S. Mondal, M. Myška, L. Novotný, V. Petousis, S. Pospíšil, K. Smolek, A. Sopczak, V. Vacek, P. Vokáč
Klíčová slovaKeywords
hadron, calorimeter, ATLAS detector, pions
ExperimentCollaboration
ATLAS
DOIDOI
10.1140/epjc/s10052-022-10117-2
Časopis / citaceJournal / citation
The European Physical Journal C 82(3), 223 (2022) · ISSN 1434-6044
RokYear
2022
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Centrum pokročilých aplikovaných přírodních vědCenter for advanced applied sciences; Získávání nových poznatků o mikrosvětě v infrastruktuře CERNAcquiring new pieces of knowledge about micro-world in CERN research infrastructure; CERN-CZ II - Výzkumná infrastruktura pro experimenty v CERN - LM2018104 (2020–2022)CERN-CZ II - Výzkumná infrastruktura pro experimenty v CERN - LM2018104 (2020–2022)
CitovánoCited by
20 (INSPIRE-HEP)
2022: 32023: 82024: 72025: 2
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

The energy response of the ATLAS calorimeter is measured for single charged pions with transverse momentum in the range 10<p(T) < 300 GeV. The measurement is performed using 139 fb(-1) of LHC proton-proton collision data at root s =13 TeV taken in Run 2 by the ATLAS detector. Charged pions originating from tau-lepton decays are used to provide a sample of high-p(T) isolated particles, where the composition is known, to test an energy regime that has not previously been probed by in situ single-particle measurements. The calorimeter response to single-pions is observed to be overestimated by similar to 2% across a large part of the p(T) spectrum in the central region and underestimated by similar to 4% in the endcaps in the ATLAS simulation. The uncertainties in the measurements are less than or similar to 1% for 15<p(T) <185 GeV in the central region. To investigate the source of the discrepancies, the width of the distribution of the ratio of calorimeter energy to track momentum, the energies per layer and response in the hadronic calorimeter are also compared between data and simulation.

The energy response of the ATLAS calorimeter is measured for single charged pions with transverse momentum in the range 10<p(T) < 300 GeV. The measurement is performed using 139 fb(-1) of LHC proton-proton collision data at root s =13 TeV taken in Run 2 by the ATLAS detector. Charged pions originating from tau-lepton decays are used to provide a sample of high-p(T) isolated particles, where the composition is known, to test an energy regime that has not previously been probed by in situ single-particle measurements. The calorimeter response to single-pions is observed to be overestimated by similar to 2% across a large part of the p(T) spectrum in the central region and underestimated by similar to 4% in the endcaps in the ATLAS simulation. The uncertainties in the measurements are less than or similar to 1% for 15<p(T) <185 GeV in the central region. To investigate the source of the discrepancies, the width of the distribution of the ratio of calorimeter energy to track momentum, the energies per layer and response in the hadronic calorimeter are also compared between data and simulation.