Ústav technické a experimentální fyziky Institute of Experimental and Applied Physics

Experimental Determination of the Charge Carrier Transport Models for Improving the Simulation of the HR GaAs:Cr Detectors’ Response

NázevTitle
Experimental Determination of the Charge Carrier Transport Models for Improving the Simulation of the HR GaAs:Cr Detectors’ ResponseExperimental Determination of the Charge Carrier Transport Models for Improving the Simulation of the HR GaAs:Cr Detectors’ Response
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
P. Smolyanskiy, P. Burian, M. Sitarz, B. Bergmann
DOIDOI
10.3390/s23156886
Časopis / citaceJournal / citation
Sensors. 2023, 23(15), ISSN 1424-8220.
RokYear
2023
JazykLanguage
eng
WoSWoS
001046876000001
ScopusScopus
2-s2.0-85167869811
RIVRIV
RIV/68407700:21670/23:00367612!RIV24-GA0-21670___
ProjektProject
Identifikace částic v experimentech fysiky vysokych energií a ve vesmíru s pokročilými detekčními systémyParticle identification in high-energy physics experiments and space with advanced detection systems

AbstraktAbstract

The response of Timepix3 detectors with 300 µm and 500 µm thick HR GaAs:Cr sensors was studied with particle beams at the Danish Centre for Particle Therapy in Aarhus, Denmark. Therefore, the detectors were irradiated at different angles with protons of 240 MeV. The precise per-pixel time and energy measurements were exploited in order to determine the charge carrier transport properties. Using the tracks left by the penetrating charged particles hitting the sensor at the grazing angle, we were able to determine the charge collection efficiency, the charge carrier drift times across the sensor thickness, the dependency of the electron, and for the first time, the hole drift velocity on the electric field. Moreover, extracting the dependence of the charge cloud size on the interaction depth for different bias voltages, it was possible to determine the dependence of the diffusion coefficient on the applied bias voltage. A good agreement was found with the previously reported values for n-type GaAs. The measurements were conducted for different detector assemblies to estimate the systematic differences between them, and to generalize the results. The experimental findings were implemented into the Allpix Squared simulation framework and validated by a comparison of the measurement and simulation for the Am-241 𝛾-ray source

The response of Timepix3 detectors with 300 µm and 500 µm thick HR GaAs:Cr sensors was studied with particle beams at the Danish Centre for Particle Therapy in Aarhus, Denmark. Therefore, the detectors were irradiated at different angles with protons of 240 MeV. The precise per-pixel time and energy measurements were exploited in order to determine the charge carrier transport properties. Using the tracks left by the penetrating charged particles hitting the sensor at the grazing angle, we were able to determine the charge collection efficiency, the charge carrier drift times across the sensor thickness, the dependency of the electron, and for the first time, the hole drift velocity on the electric field. Moreover, extracting the dependence of the charge cloud size on the interaction depth for different bias voltages, it was possible to determine the dependence of the diffusion coefficient on the applied bias voltage. A good agreement was found with the previously reported values for n-type GaAs. The measurements were conducted for different detector assemblies to estimate the systematic differences between them, and to generalize the results. The experimental findings were implemented into the Allpix Squared simulation framework and validated by a comparison of the measurement and simulation for the Am-241 𝛾-ray source