ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Characterizing the response of Timepix solid state detectors to dust impacts

NázevTitle
Characterizing the response of Timepix solid state detectors to dust impactsCharacterizing the response of Timepix solid state detectors to dust impacts
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
L. Nouzak, J. Broulím, J. Fontanese, K. Masek
Klíčová slovaKeywords
Timepix solid state detector, Dust detection, Position sensing, Dust impact, Dust accelerator
DOIDOI
10.1016/j.icarus.2024.116155
Časopis / citaceJournal / citation
Icarus 418, 116155 (2024) · ISSN 0019-1035
RokYear
2024
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Institucionální podpora na rozvoj výzkumné org.Institucionální podpora na rozvoj výzkumné org.
CitovánoCited by
2 (OpenAlex)
2025: 12026: 1
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

Timepix Solid State Detectors (TSSDs) are used in a range of applications, including high energy particle physics, x-ray imaging spectroscopy, medical imaging, radiation monitors and compact dosimeters. In space sciences, such detectors have been used for characterizing the radiation environments of the Earth and lunar surface. This study is a pilot investigation of the response of TSSDs to high-velocity dust impacts. The setup used for the measurements is a silicon slab with 500 mu m thickness combined with the Timepix 2 read-out chip with a pixel size of 55 x 55 mu m2. The outer surface of the SSD is coated with a 150 nm thick layer of aluminum to eliminate the sensitivity to light. The dust accelerator facility operated at the University of Colorado is used to expose the TSSD to micron- and sub-micron sized iron particles in a velocity range of 1-10 km/s. A fraction (5%) of the impacting dust particles were detected by the TSSD. The primary mechanism of the detection is through the light generated upon the impact and the charge signal spreads over multiple pixels. The fraction of dust particles kinetic energy that is converted to detectable charge on the TSSD is small, in the range of 10-3 - 10-6. The largest craters generated by the dust impacts were examined using a scanning electron microscope (SEM). The SEM images confirm that the particles penetrated the aluminum layer and the craters contain iron residue from the dust material. Over the investigated impact parameter range, the TSSD does not suffer a permanent damage from the dust impacts. Due to their small size and relatively low sensitivity to dust impacts, TSSDs could be used as dust detectors only in environments with high dust fluxes (e.g., in cometary trails), or where the precision measurements of the impact location are desired.

Timepix Solid State Detectors (TSSDs) are used in a range of applications, including high energy particle physics, x-ray imaging spectroscopy, medical imaging, radiation monitors and compact dosimeters. In space sciences, such detectors have been used for characterizing the radiation environments of the Earth and lunar surface. This study is a pilot investigation of the response of TSSDs to high-velocity dust impacts. The setup used for the measurements is a silicon slab with 500 mu m thickness combined with the Timepix 2 read-out chip with a pixel size of 55 x 55 mu m2. The outer surface of the SSD is coated with a 150 nm thick layer of aluminum to eliminate the sensitivity to light. The dust accelerator facility operated at the University of Colorado is used to expose the TSSD to micron- and sub-micron sized iron particles in a velocity range of 1-10 km/s. A fraction (5%) of the impacting dust particles were detected by the TSSD. The primary mechanism of the detection is through the light generated upon the impact and the charge signal spreads over multiple pixels. The fraction of dust particles kinetic energy that is converted to detectable charge on the TSSD is small, in the range of 10-3 - 10-6. The largest craters generated by the dust impacts were examined using a scanning electron microscope (SEM). The SEM images confirm that the particles penetrated the aluminum layer and the craters contain iron residue from the dust material. Over the investigated impact parameter range, the TSSD does not suffer a permanent damage from the dust impacts. Due to their small size and relatively low sensitivity to dust impacts, TSSDs could be used as dust detectors only in environments with high dust fluxes (e.g., in cometary trails), or where the precision measurements of the impact location are desired.

↑ NahoruTop