ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

Heavy ion charge and velocity resolution with a Medipix-based active Space Radiation Dosimeter

NázevTitle
Heavy ion charge and velocity resolution with a Medipix-based active Space Radiation DosimeterHeavy ion charge and velocity resolution with a Medipix-based active Space Radiation Dosimeter
Druh výsledkuResult type
Příspěvek ve sborníkuProceedings paper
AutořiAuthors
L. S. Pinsky, A. Empl, N. Stoffle, C. Leroy, A. Gutierrez, J. Jakůbek, S. Pospíšil, H. Kitamura, Y. Uchihori, Y. Nakahiro, J. Miller, C. Zeitlin
Klíčová slovaKeywords
Medipix2, pixel detector, resolution, linear energy transfer, space radiation dosimeter
KonferenceConference
2010 IEEE Aerospace Conference Proceedings (Big Sky (Montana), 2010-03-06)
DOIDOI
10.1109/AERO.2010.5447007
Časopis / citaceJournal / citation
In: 2010 IEEE Aerospace Conference, IEEE, 2010, pp. 1-6 · ISSN 1095-323X
RokYear
2010
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Využití radionuklidů a ionizujícího zářeníApplication of radionuclides and ionising radiation; Spolupráce ČR s CERNCollaboration of the Czech Republic with CERN; Fundamentální experimenty ve fyzice mikrosvětaFundamental Experiments in Physics of Microworld
CitovánoCited by
4 (OpenAlex)
2012: 12013: 02014: 12015: 02016: 12017: 02018: 02019: 02020: 02021: 02022: 02023: 02024: 02025: 1
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

In preparation for the development of an active Space Radiation Dosimeter based on the Medipix2 pixel ASIC technology developed at CERN in Geneva, Switzerland, exposures were made at the HIMAC facility in Japan with a TimePix-based version with a Si detector layer to explore the potential for discrimination between tracks with differing charges and energies, but with very similar dE/dx values. Data were taken in February 2009 at 15 degree increments for a number of different beams including 600 and 800 MeV/A Si, 180 MeV/A Ne and 100 MeV/A O. Data were also obtained for 400 MeV/A Si and 500 MeV/A Fe along with 290 and 180 MeV/A N. The TimePix chips have been calibrated to achieve the maximum resolution. One of the principal objectives of these data runs was to explore the resolution of TimePix-based Si detectors to discriminate between various ions with different energies and charges, but with similar dE/dx values in Si.

In preparation for the development of an active Space Radiation Dosimeter based on the Medipix2 pixel ASIC technology developed at CERN in Geneva, Switzerland, exposures were made at the HIMAC facility in Japan with a TimePix-based version with a Si detector layer to explore the potential for discrimination between tracks with differing charges and energies, but with very similar dE/dx values. Data were taken in February 2009 at 15 degree increments for a number of different beams including 600 and 800 MeV/A Si, 180 MeV/A Ne and 100 MeV/A O. Data were also obtained for 400 MeV/A Si and 500 MeV/A Fe along with 290 and 180 MeV/A N. The TimePix chips have been calibrated to achieve the maximum resolution. One of the principal objectives of these data runs was to explore the resolution of TimePix-based Si detectors to discriminate between various ions with different energies and charges, but with similar dE/dx values in Si.

↑ NahoruTop