ÚTEFČVUT Ústav technické a experimentální fyziky ČVUT v PrazeInstitute of Experimental and Applied Physics, CTU in Prague

USB Lite-Miniaturized readout interface for Medipix2 detector

NázevTitle
USB Lite-Miniaturized readout interface for Medipix2 detectorUSB Lite-Miniaturized readout interface for Medipix2 detector
Druh výsledkuResult type
Článek v časopiseJournal article
AutořiAuthors
Z. Vykydal, J. Jakůbek
Klíčová slovaKeywords
Medipix, X-ray imaging, data acquisition, USB interface, Spectroscopy
DOIDOI
10.1016/j.nima.2010.06.118
Časopis / citaceJournal / citation
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 633, S48-S49 (2011) · ISSN 0168-9002
RokYear
2011
JazykLanguage
eng
ZáznamyRecords
ProjektProject
Příprava, modifikace a charakterizace materiálů energetickým zářenímPreparation, Modification and Characterization of Materials by Energetic Radiation; Využití radionuklidů a ionizujícího zářeníApplication of radionuclides and ionising radiation
CitovánoCited by
32 (OpenAlex)
2011: 12012: 32013: 12014: 32015: 22016: 32017: 52018: 32019: 42020: 22021: 12022: 22023: 02024: 12025: 02026: 1
Citace ke staženíDownload citation
TXT · BibTeX

AbstraktAbstract

Nowadays, the Medipix2 detector is widely used in many different fields of applications and for some of them the size of the system becomes the critical issue. Therefore we manufactured the miniaturized version of currently used USB interface accommodating the Medipix2 chip on the same printed circuit board as the readout electronics. The dimensions of the whole device are 15 x 60 mm(2) (25% out of it is actually sensitive area). It incorporates all the necessary detector support including the back-side pulse processing circuits and the high voltage source for detector bias (up to 100 V) and it is fully powered from the USB bus. The readout speed of the Medipix2 chip is about 4 fps.

Nowadays, the Medipix2 detector is widely used in many different fields of applications and for some of them the size of the system becomes the critical issue. Therefore we manufactured the miniaturized version of currently used USB interface accommodating the Medipix2 chip on the same printed circuit board as the readout electronics. The dimensions of the whole device are 15 x 60 mm(2) (25% out of it is actually sensitive area). It incorporates all the necessary detector support including the back-side pulse processing circuits and the high voltage source for detector bias (up to 100 V) and it is fully powered from the USB bus. The readout speed of the Medipix2 chip is about 4 fps.

↑ NahoruTop